On Sun, Sep 12, 2010 at 5:54 PM, Mahjoub Kamel <mahjoubkame...@gmail.com> wrote:
> I installed openOCD 0.4.0 through the windows installer.
> I m using one LPT wiggler interface to connect to the LPC2212 nxp micro
>
> C:\Program Files\OpenOCD\0.4.0\bin>openocd.exe -f openocd.cfg
> Open On-Chip Debugger 0.4.0 (2010-02-22-19:05)
> Licensed under GNU GPL v2
> For bug reports, read
>         http://openocd.berlios.de/doc/doxygen/bugs.html
> parport port = 0x378
> shutdown command invoked
> Error: missing privileges for direct i/o
> Command handler execution failed

I do not have wiggler. But did you install giveio?
C:\Program Files\OpenOCD\0.4.0\drivers\giveio.zip

BTW, the above one will not work properly under
64bit Windows. But this is not your problem.
The way to go for 64bit may be to use this one.
http://www.highrez.co.uk/Downloads/InpOut32/default.htm

-- 
Xiaofan