On 19/06/2011 7:49 a.m., Roy Sigurd Karlsbakk wrote:
Hi all

I have a few machines setup with OI 148, and I can't make the LEDs on the 
drives work when something goes bad. The chassies are supermicro ones, and work 
well, normally. Any idea how to make drive LEDs wirk with this setup?

Hi Roy,

There is no support in the OS, on generic hardware, for this sort of functionality.

It "could" be coded in on most systems where ses and ipmi support is present, since much of the functionality is present, but doing this this 'way' outside my comfort zone.

LSI 6gb IT mode HBA's don't support ses at present.

Cmd line tools to blink led's will probably be available in the next Sol11 release.

For compatible lsi sas2 controllers, sas2ircu supports a locate function blink leds.



As an aside, I have built a fully functional "7210 Unified Storage Server Clone" running on Supermicro hardware and some customised definitions in the management software to match the new hardware. That setup fully supported drive locator and failure indications, so the generic hardware can do it with the right software.


Mark.




_______________________________________________
OpenIndiana-discuss mailing list
OpenIndiana-discuss@openindiana.org
http://openindiana.org/mailman/listinfo/openindiana-discuss

Reply via email to