Trying to help someone on a public forum. He is trying out OI per my advice. He has a two-vdev raidz2 pool, with one spare drive. One drive apparently died, so it is showing as removed. He was surprised the spare didn't kick in. I told him to do 'zpool replace POOL OLDDEV NEWDEV'. He did and got "cannot replace c5t7d0 with c2t1d0: devices have different sector alignment". I had him do a 'prtvtoc' on both devices, and they look absolutely identical! This doesn't look right, does it? I'm having him try a couple of things: 1) use the '-f' flag to try to force it, or 2) power off, unplug the dead drive, plug the spare into the same slot and reboot (possibly doing 'zpool replace POOL OLDDEV'. Any thoughts?