From: Zhenhua Luo <b19...@freescale.com>

    The original issue:
    When "shutdown now" command is typed on Linux prompt, the system tries to
    shut down gracefully from runlevel 5 to 1.
    RunLevel 1 is single-user/maintenance mode. This is the default behavior
    when no runlevel option is mentioned in shutdown command (like shutdown
    -h now OR shutdown -r now).
    The startup script which starts single-user mode by initiating a new
    process is missing from /etc/rc1.d/...
    Because of this, following error appears:
        INIT: no more processes left in this runlevel
    A start-up script is needed to enables the user to log into single-user
    mode when "shutdown now" command is given.

Signed-off-by: Matthew McClintock <m...@freescale.com>
Signed-off-by: Zhenhua Luo <b19...@freescale.com>
---
 meta/recipes-core/sysvinit/sysvinit-inittab_2.88dsf.bb |    5 +++--
 1 file changed, 3 insertions(+), 2 deletions(-)

diff --git a/meta/recipes-core/sysvinit/sysvinit-inittab_2.88dsf.bb 
b/meta/recipes-core/sysvinit/sysvinit-inittab_2.88dsf.bb
index 492c60c..fe1ff41 100644
--- a/meta/recipes-core/sysvinit/sysvinit-inittab_2.88dsf.bb
+++ b/meta/recipes-core/sysvinit/sysvinit-inittab_2.88dsf.bb
@@ -2,7 +2,7 @@ DESCRIPTION = "Inittab for sysvinit"
 LICENSE = "GPLv2"
 LIC_FILES_CHKSUM = 
"file://${COREBASE}/meta/files/common-licenses/GPL-2.0;md5=801f80980d171dd6425610833a22dbe6"
 
-PR = "r7"
+PR = "r8"
 
 SRC_URI = "file://inittab"
 
@@ -26,7 +26,8 @@ do_install() {
     for i in $tmp
     do
        j=`echo ${i} | sed s/\;/\ /g`
-        echo "${idx}:2345:respawn:${base_sbindir}/getty ${j}" >> 
${D}${sysconfdir}/inittab
+       echo "${idx}:12345:respawn:${base_sbindir}/getty ${j}" >> 
${D}${sysconfdir}/inittab
+
        idx=`expr $idx + 1`
     done
 
-- 
1.7.10



_______________________________________________
Openembedded-core mailing list
Openembedded-core@lists.openembedded.org
http://lists.linuxtogo.org/cgi-bin/mailman/listinfo/openembedded-core