Expecting 1s accuracy on a 2s timeout on a heavily loaded system has proven to be unreliable. Update this to a 5s timeout with a 3s delta which should be achievable.
Signed-off-by: Richard Purdie <richard.pur...@linuxfoundation.org> --- meta/lib/oeqa/selftest/cases/runcmd.py | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/meta/lib/oeqa/selftest/cases/runcmd.py b/meta/lib/oeqa/selftest/cases/runcmd.py index d76d7063c69..a1615cfd20b 100644 --- a/meta/lib/oeqa/selftest/cases/runcmd.py +++ b/meta/lib/oeqa/selftest/cases/runcmd.py @@ -24,8 +24,8 @@ class RunCmdTests(OESelftestTestCase): # The delta is intentionally smaller than the timeout, to detect cases where # we incorrectly apply the timeout more than once. - TIMEOUT = 2 - DELTA = 1 + TIMEOUT = 5 + DELTA = 3 @OETestID(1916) def test_result_okay(self): -- 2.19.1 -- _______________________________________________ Openembedded-core mailing list Openembedded-core@lists.openembedded.org http://lists.openembedded.org/mailman/listinfo/openembedded-core