Today I upgraded from zeek-2.6-beta2 and pf_ring 7.3.0

  PF_RING 7.3.0 ($Revision: dev:c85efbc90d5abb7ef471be17cf9192b88a842ac4$)

to zeek 2.6.1 and the latest pf_ring from git

  PF_RING 7.5.0 ($Revision: dev:342b85fe63a2f0cdd70cd16fefebe99e6a8657af$)

My interfaces were configured like so to work with zbalance_ipc :

  [worker-1]
  type=worker
  host=localhost
  interface=zc:99@0
  lb_method=pf_ring
  lb_procs=1

  [worker-2]
  type=worker
  host=localhost
  interface=zc:99@2
  lb_method=pf_ring
  lb_procs=1

etc.

When I start up zeek/bro, all the workers crash with

  fatal error: problem with interface zc:99@0@0 (pcap_error: SIOCGIFHWADDR: No 
such device (pcap_activate))

Anyone know what I need to tweak to get this to work?

Thanks,

--
Jim Hranicky
Data Security Specialist
UF Information Technology
720 SW 2nd Avenue Suite 450, North Tower, Gainesville, FL 32605