Javier,

VLAN -- or, more in general, BPF -- filters are not supported when nProbe is 
used in collector mode.


Simone

> On 10 Nov 2017, at 13:16, Javier Narváez <[email protected]> wrote:
> 
> Hi,
> 
> I am running nprobe as follows:
> nprobe --collector=none --zmq="tcp://127.0.0.1:5556" --collector-port=9996 
> --interface=none -V 10 --verbose=2
> 
> And I get a lot of lines like this with several VLAN ids:
> 10/Nov/2017 14:14:24 [engine.c:2886] Emitting Flow: [->][tcp] 5.6.7.8:63826 
> -> 1.2.3.4:80 [1 pkt/52 bytes][ifIdx 1000001->1000010][0.0 sec][VLAN 
> 190/190][init Unknown][AS: xxx -> xxx]
> 
> Would be possible to filter by VLAN and only send VLAN 190 to ntopng?
> 
> Thank you in advance, kind regards.
> Javier Narváez
> <logo-150-ancho.png>_______________________________________________
> Ntop-misc mailing list
> [email protected]
> http://listgateway.unipi.it/mailman/listinfo/ntop-misc