Hi Simone, After your message, I did try again, from scratch : I completely removed ntopng install to start again, wiped out redis completely by stopping redis-server and remove /var/lib/redis/dump.rdb, and reinstalled everything. Now is seems to work ok when ntopng is configured in collector mode.
I suppose that my first attemps failed because I first configured ntopng and nprobe in standard mode (no --zmq-probe-mode in nprobe, no 'c' in ntopn interface name) For the record, There is my working configuration : * My router (mikrotik) send flow to nprobe/ntop server on port 1236 * nprobe configuration: -n=none -G= --online-license-check -g=/var/run/nprobe.pid --collector-port=1236 --zmq=tcp://127.0.0.1:5560 --zmq-probe-mode * ntopng configuration: -G=/var/run/ntopng.pid -n=3 -i=tcp://127.0.0.1:5560c -d=/home/ntopng --daemon= -w=3000 --user=ntopng --group=ntopng --local-networks=100.64.0.0/10,10.0.0.0/8,192.168.0.0/16,172.16.0.0/12 I juqr closed the issue. Thanks. ----- Mail original ----- > De: "Simone Mainardi" <[email protected]> > À: [email protected], "Frederic Hermann" <[email protected]> > Envoyé: Mardi 24 Janvier 2017 11:41:25 > Objet: Re: [Ntop-misc] How to get separate traffic statistic by collector > interface > Hi, I tried to reproduce but everything works as expected. Full reply is on > the > issue page. I encourage you to update both ntopng and nprobe to their latest > versions _______________________________________________ Ntop-misc mailing list [email protected] http://listgateway.unipi.it/mailman/listinfo/ntop-misc