Hi Simone,

After your message, I did try again, from scratch : I completely removed ntopng 
install to start again, wiped out redis completely by stopping redis-server and 
remove /var/lib/redis/dump.rdb,
and reinstalled everything.
Now is seems to work ok when ntopng is configured in collector mode.

I suppose that my first attemps failed because I first configured ntopng and 
nprobe in standard mode (no --zmq-probe-mode in nprobe, no 'c' in ntopn 
interface name)

For the record, There is my working configuration :

* My router (mikrotik) send flow to nprobe/ntop server on port 1236

* nprobe configuration:
-n=none -G= --online-license-check -g=/var/run/nprobe.pid --collector-port=1236 
--zmq=tcp://127.0.0.1:5560 --zmq-probe-mode

* ntopng configuration:
-G=/var/run/ntopng.pid -n=3 -i=tcp://127.0.0.1:5560c -d=/home/ntopng --daemon= 
-w=3000 --user=ntopng --group=ntopng 
--local-networks=100.64.0.0/10,10.0.0.0/8,192.168.0.0/16,172.16.0.0/12

I juqr closed the issue. 

Thanks.


----- Mail original -----
> De: "Simone Mainardi" <[email protected]>
> À: [email protected], "Frederic Hermann" <[email protected]>
> Envoyé: Mardi 24 Janvier 2017 11:41:25
> Objet: Re: [Ntop-misc] How to get separate traffic statistic by collector 
> interface

> Hi, I tried to reproduce but everything works as expected. Full reply is on 
> the
> issue page. I encourage you to update both ntopng and nprobe to their latest
> versions
_______________________________________________
Ntop-misc mailing list
[email protected]
http://listgateway.unipi.it/mailman/listinfo/ntop-misc

Reply via email to