sanpwc commented on code in PR #4821: URL: https://github.com/apache/ignite-3/pull/4821#discussion_r1899686724
########## modules/raft/src/main/java/org/apache/ignite/internal/raft/server/impl/JraftServerImpl.java: ########## @@ -447,6 +447,10 @@ public boolean startRaftNode( // Thread pools are shared by all raft groups. NodeOptions nodeOptions = opts.copy(); + // Then a new election starts on a node, it has local physical time higher than last generated safe ts + // because we wait out the clock skew. + nodeOptions.setElectionTimeoutMs(Math.max(nodeOptions.getElectionTimeoutMs(), groupOptions.maxClockSkew())); Review Comment: So, it's required for getLeaderLeaseTimeoutMs to be >= maxClockSkew, right? Seems that it's not guaranteed because it's possible to set any value using org.apache.ignite.raft.jraft.option.NodeOptions#setElectionTimeoutMs. With defaults it should work though. -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: notifications-unsubscr...@ignite.apache.org For queries about this service, please contact Infrastructure at: us...@infra.apache.org