rpuch commented on code in PR #4684:
URL: https://github.com/apache/ignite-3/pull/4684#discussion_r1833856630


##########
modules/replicator/src/main/java/org/apache/ignite/internal/replicator/ReplicaManager.java:
##########
@@ -1086,16 +1097,64 @@ private void idleSafeTimeSync() {
         }
     }
 
-    private void sendSafeTimeSyncIfReplicaReady(CompletableFuture<Replica> 
replicaFuture) {
-        if (isCompletedSuccessfully(replicaFuture)) {
-            Replica replica = replicaFuture.join();
+    private void sendSafeTimeSyncIfReplicaReady(CompletableFuture<Replica> 
replicaFuture, HybridTimestamp proposedSafeTime) {
+        if (!isCompletedSuccessfully(replicaFuture)) {
+            return;
+        }
 
-            ReplicaSafeTimeSyncRequest req = 
REPLICA_MESSAGES_FACTORY.replicaSafeTimeSyncRequest()
-                    .groupId(toReplicationGroupIdMessage(replica.groupId()))
-                    .build();
+        Replica replica = replicaFuture.join();
 
-            replica.processRequest(req, localNodeId);
+        if (!shouldAdvanceIdleSafeTime(replica, proposedSafeTime)) {
+            // If previous attempt might still be waiting on the Metastorage 
SafeTime, we should not send the command ourselves as this
+            // might be an indicator that Metastorage SafeTime has stuck for 
some time; if we send the command, it will have to add its
+            // future, increasing (most probably, uselessly) heap pressure.
+            return;
         }
+
+        getOrCreateContext(replica).lastIdleSafeTimeProposal = 
proposedSafeTime;
+
+        ReplicaSafeTimeSyncRequest req = 
REPLICA_MESSAGES_FACTORY.replicaSafeTimeSyncRequest()
+                .groupId(toReplicationGroupIdMessage(replica.groupId()))
+                .proposedSafeTime(proposedSafeTime)
+                .build();
+
+        replica.processRequest(req, localNodeId).whenComplete((res, ex) -> {
+            if (ex != null) {
+                LOG.error("Could not advance safe time for {} to {}", 
replica.groupId(), proposedSafeTime);
+            }
+        });
+    }
+
+    private boolean shouldAdvanceIdleSafeTime(Replica replica, HybridTimestamp 
proposedSafeTime) {
+        if (placementDriver.getCurrentPrimaryReplica(replica.groupId(), 
proposedSafeTime) != null) {

Review Comment:
   We call `clock.now()` just once for the whole batch; so for each individual 
replica, `clock.now()` is not called, and there are no such calls that can be 
saved



-- 
This is an automated message from the Apache Git Service.