Ok. What is the best way to drop this interval in nfsen? In my
%sources I have added the optarg -t 60, and this has the expected
outcome of nfcapd rolling files every 60 seconds. However, this seems
to break nfprofile because my data in the nfsen dashboard now appears
to be sourced off only that last 1 minute file and treated as 5
minutes worth of data. (ie. instead of 6+gbps, it now shows about
900mbps-1.1gbps).

Is there some other way I need to be setting this interval in nfsen.conf?

On Fri, Nov 14, 2014 at 11:44 AM, Phil Mayers <p.may...@imperial.ac.uk> wrote:
> I don't believe nfcapd.current is valid for reading while it's still being
> written.
>
> I would just drop your interval down to one minute. If you need less than
> one minute latency I have no suggestion.
> --