20g-capable devices are not configured properly for self-test, using 10g as their speed which cause the link indication to remain down and fail the internal loopback test.
Signed-off-by: Yuval Mintz <yuval.mi...@qlogic.com> Signed-off-by: Ariel Elior <ariel.el...@qlogic.com> --- drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c | 12 ++++++++---- 1 file changed, 8 insertions(+), 4 deletions(-) diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c index c1033a5..3df03bb 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c @@ -2347,12 +2347,16 @@ int bnx2x_initial_phy_init(struct bnx2x *bp, int load_mode) if (load_mode == LOAD_DIAG) { struct link_params *lp = &bp->link_params; lp->loopback_mode = LOOPBACK_XGXS; - /* do PHY loopback at 10G speed, if possible */ - if (lp->req_line_speed[cfx_idx] < SPEED_10000) { + /* Prefer doing PHY loopback at highest speed */ + if (lp->req_line_speed[cfx_idx] < SPEED_20000) { if (lp->speed_cap_mask[cfx_idx] & - PORT_HW_CFG_SPEED_CAPABILITY_D0_10G) + PORT_HW_CFG_SPEED_CAPABILITY_D0_20G) lp->req_line_speed[cfx_idx] = - SPEED_10000; + SPEED_20000; + else if (lp->speed_cap_mask[cfx_idx] & + PORT_HW_CFG_SPEED_CAPABILITY_D0_10G) + lp->req_line_speed[cfx_idx] = + SPEED_10000; else lp->req_line_speed[cfx_idx] = SPEED_1000; -- 1.9.3 -- To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to majord...@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html