Chuck Ebbert wrote:
Megahertz EM1144 PCMCIA ethernet adapter needs special handling
because it has two VERS_1 tuples and the station address is in
the second one. Conversion to generic handling of these fields
broke it. Reverting that fixes the device.
https://bugzilla.redhat.com/show_bug.cgi?id=233255
Thanks go to Jon Stanley for not giving up on this one until the
problem was found.
Signed-off-by: Chuck Ebbert <[EMAIL PROTECTED]>
---
This was broken for over a year before the problem was found...
applied
--
To unsubscribe from this list: send the line "unsubscribe netdev" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at http://vger.kernel.org/majordomo-info.html