Auke Kok wrote:
Since data can never exceed u32, it can't even be larger than LONG_MAX/HZ.

Signed-off-by: Auke Kok <[EMAIL PROTECTED]>
Cc: [EMAIL PROTECTED]
---

 drivers/net/pcnet32.c |    5 ++---
 1 files changed, 2 insertions(+), 3 deletions(-)

diff --git a/drivers/net/pcnet32.c b/drivers/net/pcnet32.c
index ff92aca..3573e77 100644
--- a/drivers/net/pcnet32.c
+++ b/drivers/net/pcnet32.c
@@ -1101,9 +1101,8 @@ static int pcnet32_phys_id(struct net_device *dev, u32 
data)
        mod_timer(&lp->blink_timer, jiffies);
        set_current_state(TASK_INTERRUPTIBLE);
- /* AV: the limit here makes no sense whatsoever */
-       if ((!data) || (data > (u32) (MAX_SCHEDULE_TIMEOUT / HZ)))
-               data = (u32) (MAX_SCHEDULE_TIMEOUT / HZ);
+       if (!data)
+               data = INT_MAX;
msleep_interruptible(data * 1000);
        del_timer_sync(&lp->blink_timer);

Two comments:

1) I would prefer to pick a sane limit, like "1 day". The unit of 'data' is seconds, so IMO we should not allow stupid timeouts, much less INT_MAX ones :) But hey, then again, maybe we should permit root to hang themselves with own rope...

2) [tangent] someone really should add the obvious ssleep_interruptible()

-
To unsubscribe from this list: send the line "unsubscribe netdev" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to