On Tue, 13 Apr 2021 00:05:51 +0200 Tobias Waldekranz <tob...@waldekranz.com> wrote:
> On Mon, Apr 12, 2021 at 23:50, Marek Behun <marek.be...@nic.cz> wrote: > > On Mon, 12 Apr 2021 23:22:45 +0200 > > Tobias Waldekranz <tob...@waldekranz.com> wrote: > > > >> On Mon, Apr 12, 2021 at 21:30, Marek Behun <marek.be...@nic.cz> wrote: > >> > On Mon, 12 Apr 2021 14:46:11 +0200 > >> > Tobias Waldekranz <tob...@waldekranz.com> wrote: > >> > > >> >> I agree. Unless you only have a few really wideband flows, a LAG will > >> >> typically do a great job with balancing. This will happen without the > >> >> user having to do any configuration at all. It would also perform well > >> >> in "router-on-a-stick"-setups where the incoming and outgoing port is > >> >> the same. > >> > > >> > TLDR: The problem with LAGs how they are currently implemented is that > >> > for Turris Omnia, basically in 1/16 of configurations the traffic would > >> > go via one CPU port anyway. > >> > > >> > > >> > > >> > One potencial problem that I see with using LAGs for aggregating CPU > >> > ports on mv88e6xxx is how these switches determine the port for a > >> > packet: only the src and dst MAC address is used for the hash that > >> > chooses the port. > >> > > >> > The most common scenario for Turris Omnia, for example, where we have 2 > >> > CPU ports and 5 user ports, is that into these 5 user ports the user > >> > plugs 5 simple devices (no switches, so only one peer MAC address for > >> > port). So we have only 5 pairs of src + dst MAC addresses. If we simply > >> > fill the LAG table as it is done now, then there is 2 * 0.5^5 = 1/16 > >> > chance that all packets would go through one CPU port. > >> > > >> > In order to have real load balancing in this scenario, we would either > >> > have to recompute the LAG mask table depending on the MAC addresses, or > >> > rewrite the LAG mask table somewhat randomly periodically. (This could > >> > be in theory offloaded onto the Z80 internal CPU for some of the > >> > switches of the mv88e6xxx family, but not for Omnia.) > >> > >> I thought that the option to associate each port netdev with a DSA > >> master would only be used on transmit. Are you saying that there is a > >> way to configure an mv88e6xxx chip to steer packets to different CPU > >> ports depending on the incoming port? > >> > >> The reason that the traffic is directed towards the CPU is that some > >> kind of entry in the ATU says so, and the destination of that entry will > >> either be a port vector or a LAG. Of those two, only the LAG will offer > >> any kind of balancing. What am I missing? > > > > Via port vectors you can "load balance" by ports only, i.e. input port X > > -> trasmit via CPU port Y. > > How is this done? In a case where there is no bridging between the > ports, then I understand. Each port could have its own FID. But if you > have this setup... > > br0 wan > / \ > lan0 lan1 > > lan0 and lan1 would use the same FID. So how could you say that frames > from lan0 should go to cpu0 and frames from lan1 should go to cpu1 if > the DA is the same? What would be the content of the ATU in a setup > like that? > > > When using LAGs, you are load balancing via hash(src MAC | dst mac) > > only. This is better in some ways. But what I am saying is that if the > > LAG mask table is static, as it is now implemented in mv88e6xxx code, > > then for many scenarios there is a big probability of no load balancing > > at all. For Turris Omnia for example there is 6.25% probability that > > the switch chip will send all traffic to the CPU via one CPU port. > > This is because the switch chooses the LAG port only from the hash of > > dst+src MAC address. (By the 1/16 = 6.25% probability I mean that for > > cca 1 in 16 customers, the switch would only use one port when sending > > data to the CPU). > > > > The round robin solution here is therefore better in this case. > > I agree that it would be better in that case. I just do not get how you > get the switch to do it for you. I thought that this is configured in the mv88e6xxx_port_vlan() function. For each port, you specify via which ports data can egress. So for ports 0, 2, 4 you can enable CPU port 0, and for ports 1 and 3 CPU port 1. Am I wrong? I confess that I did not understand this into the most fine details, so it is entirely possible that I am missing something important and am completely wrong. Maybe this cannot be done. Marek