On Thu, Mar 11, 2021 at 9:41 AM Andrew Lunn <and...@lunn.ch> wrote: > > On Wed, Mar 10, 2021 at 06:09:52PM -0800, Ilya Lipnitskiy wrote: > > A recent change to MIPS ralink reset logic made it so mt7530 actually > > resets the switch on platforms such as mt7621 (where bit 2 is the reset > > line for the switch). That exposed an issue where the switch would not > > function properly in TRGMII mode after a reset. > > > > Reconfigure core clock in TRGMII mode to fix the issue. > > > > Tested on Ubiquiti ER-X (MT7621) with TRGMII mode enabled. > > Please don't submit the same patch to net and net-next. Anything > which is accepted into net, will get merged into net-next about a week > later. If your other two patches depend on this patch, you need to > wait for the merge to happen, then submit them. I don't mind waiting, but it's been more than a week now. When is the next merge of net-next into net planned to happen?