AR8035 recently gained MDIX support. The same functions will work for the AR8031/33 PHY. We just need to add the at803x_config_aneg() callback.
This was tested on a Kontron sl28 board. Signed-off-by: Michael Walle <mich...@walle.cc> --- drivers/net/phy/at803x.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/net/phy/at803x.c b/drivers/net/phy/at803x.c index d67bddc111e3..c2aa4c92edde 100644 --- a/drivers/net/phy/at803x.c +++ b/drivers/net/phy/at803x.c @@ -1190,6 +1190,7 @@ static struct phy_driver at803x_driver[] = { .probe = at803x_probe, .remove = at803x_remove, .config_init = at803x_config_init, + .config_aneg = at803x_config_aneg, .soft_reset = genphy_soft_reset, .set_wol = at803x_set_wol, .get_wol = at803x_get_wol, -- 2.20.1