On Wed, May 16, 2007 at 01:00:08PM +0200, Stefan Roese wrote: > This patch fixes a bug where the link speed change was not > detected correctly. This occured on a 440SPe (EMAC4) system > where the old link speed was 100Mbps and the new link speed > is 1000Mbps.
Good catch, Stefan. Unfortunately, I have to NACK your patch - you broke non EMAC4 builds. Correct fix is just to remove EMAC_MR1_MF_1000GPCS from the first if condition. I'll send correct fix shortly along with other queued patches. -- Eugene - To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to [EMAIL PROTECTED] More majordomo info at http://vger.kernel.org/majordomo-info.html