On Mon, 12 Oct 2020 14:04:22 +0000 Henrik Bjoernlund wrote:
> +     if (config->mdlevel > 7) {
> +             NL_SET_ERR_MSG_MOD(extack,
> +                                "MD level is invalid");
> +             return -EINVAL;
> +     }
> +     /* The MEP-ID is a 13 bit field in the CCM PDU identifying the MEP */
> +     if (config->mepid > 0x1FFF) {
> +             NL_SET_ERR_MSG_MOD(extack,
> +                                "MEP-ID is invalid");
> +             return -EINVAL;
> +     }

If I'm reading patch 7 correctly these parameters come from netlink,
right? In that case please use the netlink policies to check things
like ranges or correct values.