On Mon, 5 Mar 2007, Joy Latten wrote:

> 5. Around the time the set of SAs for OUT direction are to be
>    inserted into SAD, I see another ACQUIRE happening.
>    
>    I have not yet figured out where this second ACQUIRE comes from
>    and why it happens. As long as the minimal SA or set of valid outgoing
>    SAs exist in SAD, an ACQUIRE should not happen.

I saw something similar to this some time ago when testing various 
failure modes, and discused it with Herbert.

IIRC, there's a larval SA which is not torn down properly by Racoon once 
the full SA is established, and the larval SA keeps resending until it 
times out.