On 06/06/2019 5:43, Richard Cochran wrote:
> On Wed, Jun 05, 2019 at 07:28:38PM +0000, Shalom Toledo wrote:
>> So, there is an HW machine which responsible for adding UTC timestamp on
>> R-SPAN mirror packets and there is no connection to the HW free running
>> counter.
> 
> If there is no connection, then the frequency adjustments to the HW
> clock will not work as expected.

I mean that these are two different peaces of HW with different control
interfaces.

> 
> Perhaps the free running counter and the HW clock share the same clock
> source?

Yes, of course.

> 
> Thanks,
> Richard
> 

Reply via email to