> > > +/* Serial Management Interface (SMI) uses the following frame format:
> > > + *
> > > + *       preamble|start|Read/Write|  PHY   |  REG  |TA|   Data bits      
> > > | Idle
> > > + *               |frame| OP code  |address |address|  |                  
> > > |
> > > + * read | 32x1´s | 01  |    00    | 1xRRR  | RRRRR |Z0| 00000000DDDDDDDD 
> > > |  Z
> > > + * write| 32x1´s | 01  |    00    | 0xRRR  | RRRRR |10| xxxxxxxxDDDDDDDD 
> > > |  Z
> > > + *
> > > + * The register number is encoded with the 5 least significant bits in 
> > > REG
> > > + * and the 3 most significant bits in PHY
> > > + */
> > > +#define MII_ADDR_SMI0 (1<<31)
> > > +
> > 
> > Michael
> > 
> > This is a Micrel Proprietary protocol. So we should reflect this in
> > the name. MII_ADDR_MICREL_SMI? Why the 0? Are there different
> > versions? Maybe replace all SMI0 with MICREL_SMI in mdio-bitbang.c
> 
> There are two variants of the SMI interface.

Hi Michael

O.K, that explains the 0.

> 
> The KSZ8863/73/93 Products use the above Variant described as "SMI0".
> 
> The KSZ8864/95 Products use another layout:
> 
>       preamble|start|Read/Write|  PHY   |  REG  |TA|   Data bits      | Idle
>               |frame| OP code  |address |address|  |                  |
> read | 32x1´s | 01  |    10    | RR11R  | RRRRR |Z0| 00000000DDDDDDDD |  Z
> write| 32x1´s | 01  |    01    | RR11R  | RRRRR |10| xxxxxxxxDDDDDDDD |  Z
> 
> So they describe their write/read operation in the OP code rather then
> the PHY address.

At a first look, i think a standard MDIO bus controller can do this?
If so, we don't need a second define, just some code in the switch
driver which shuffles bits around.

> 
> We could change the SMI index to SMI_KSZ88X3 for the current SMI0 to
> give it a more descriptive name.

That seems sensible. In the mv88e6xxx driver, we name things based on
the first device to introduce the feature.

    Andrew

Reply via email to