The 12/20/2018 11:31, Andrew Lunn wrote: > On Thu, Dec 20, 2018 at 10:08:16AM +0100, Steen Hegelund wrote: > > When doing indirect access in the Ocelot chip, a command is setup, > > issued and then we need to poll until the result is ready. The polling > > timeout is specified in milliseconds in the datasheet and not in > > register access attempts. > > > > Signed-off-by: Steen Hegelund <[email protected]> > > Hi Steen > > Have you seen real issues with this code? You have marked this for > net, indicating it is a bug fix. If it is a real fix, please provide a > fixes: tag. > > Thanks > Andrew
Hi Andrew, It is not a bug on the currently supported platform, but we observed that the code does not work properly on other platforms that we want to support as the timing requirements there are different. So maybe this is rather an improvement than a fix... Should this rather go to net-next? -- BR Steen