From: Paul Blakey <pa...@mellanox.com>

If set, the firmware supports creating of flow tables with encap
enabled while VFs are configured, if we already created one
(restriction still applies on the first creation).

Signed-off-by: Paul Blakey <pa...@mellanox.com>
Reviewed-by: Or Gerlitz <ogerl...@mellanox.com>
Signed-off-by: Saeed Mahameed <sae...@mellanox.com>
---
 include/linux/mlx5/mlx5_ifc.h | 4 +++-
 1 file changed, 3 insertions(+), 1 deletion(-)

diff --git a/include/linux/mlx5/mlx5_ifc.h b/include/linux/mlx5/mlx5_ifc.h
index 15e36198f85f..963611820006 100644
--- a/include/linux/mlx5/mlx5_ifc.h
+++ b/include/linux/mlx5/mlx5_ifc.h
@@ -584,7 +584,9 @@ struct mlx5_ifc_flow_table_nic_cap_bits {
 struct mlx5_ifc_flow_table_eswitch_cap_bits {
        u8      reserved_at_0[0x1c];
        u8      fdb_multi_path_to_table[0x1];
-       u8      reserved_at_1d[0x1e3];
+       u8      reserved_at_1d[0x1];
+       u8      multi_fdb_encap[0x1];
+       u8      reserved_at_1e[0x1e1];
 
        struct mlx5_ifc_flow_table_prop_layout_bits 
flow_table_properties_nic_esw_fdb;
 
-- 
2.17.2