On 06/02/2018 07:08 PM, Andrew Lunn wrote:
> On Sat, Jun 02, 2018 at 06:28:22PM -0500, Grygorii Strashko wrote:
> 
> Hi Grygorii
> 
> I'm just picking out one thing here... there is lots more good stuff here.
> 
>> Additional headache is PTP: we have on PHC, but both external interfaces 
>> P1/P2
>> can timestamp packets.
>   
> This should not be a problem. The Marvell switches have one PHC, but
> each port can time stamp packets using this counter. Each port has its
> own receive and transmit time stamp registers. So i don't think this
> will cause you problems.

I hope you are right - question is always in number of available options
and which one to select - and, most important, explain it to the end user :( 


For example:
phc_index is returned as part of .get_ts_info() = cpsw_get_ts_info(),
so which intf should return phc_index?

Still not tested, so jut hope ...


-- 
regards,
-grygorii