Hello Mike,

Running a few larger Brocade VDX fabrics here...

In case of that message, there is no other option not to reset that specific new switch and then re-join the device. I had that a few times, too.

It happens when you already did some configuration changes on the new switch and the older fabric members weren't aware of that.

On 30.06.2016 at 21:41 Mike Hammett wrote:
I asked on the Brocade forum, but it's largely been crickets there. I hoped 
someone here would have an idea.

One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed 
Config DB)(Trunk Primary)
The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, 
Distributed Config DB)(Trunk Primary)

I saw that means, "The DCM Configuration DB is different on both the ends of 
ISL," but I have no idea how to resolve that.


VDX-6720s running 4.1.3b.




-----
Mike Hammett
Intelligent Computing Solutions
http://www.ics-il.com



Midwest Internet Exchange
http://www.midwest-ix.com


Reply via email to