The spec allows for bridging or layer 3 but none of the major or certified manufacturers support bridging on larger platforms. (>1000 modems)
Scott Helms On Fri, May 8, 2020 at 3:56 PM Brandon Martin <lists.na...@monmotha.net> wrote: > I'm curious... > > Is it part of the DOCSIS spec that the CMTS terminates L3, or can they > bridge to IEEE 802(.3) and delegate that to some other piece of gear? > I'm unfortunately not familiar with the MSO world much at all aside from > a little bit of L1. > > -- > Brandon Martin >