On Fri, 30 Jan 2009, Ricky Beam wrote:
On Fri, 30 Jan 2009 12:57:25 -0500, adrian kok <adriankok2...@yahoo.com.hk>
wrote:
What is max mtu in jumbo frame?
That depends on the hardware. I've seen gear running as low as ~8k. I'd
have to consult standard, but I think the max is 10k (10240).
Keep in mind the switch is not the only device on the network with jumbo
frame limits. The NICs in your servers will also have limits.
Do I need to reboot the switch to take effect after
setting up it?
Again, this depends on the system. Many accept the change immediately, while
others have to rebooted or interfaces reset to effect the change.
if it doesn't need to reboot, How can I know the
switch is running fine in this mtu 9000? eg: cisco
any tools to check?
"ping" will do. Set the packet size larger than the normal MTU (1500) and
see if it crosses the network intact. If it's not working, A) the packets
will be dropped, and B) the "oversized frame" counter (among others) should
be clocking errors.
If you're sourcing the pings from a device that supports it, you can also
send the large pings with the Do Not Fragment bit set.
jms