Looks like the latest Areca firmware. Might double check. Do you have the
same issue on -current?
Hi,
I downgraded the firmware to 1.44 and tried with -current:
arc0 at pci1 dev 0 function 0 "Areca ARC-1680" rev 0x00: apic 8 int 16 (irq
10)
arc0: 4 ports, 256MB SDRAM, firmware V1.44 2008-1-31
scsibus0 at arc0: 16 targets
arc0: unable to query firmware for sensor info
however, the problem still appears:
# bioctl -v -i -h sd0
sd0: <Areca, ARC-1212-VOL#000, R001>, serial 4044af0969800952
# bioctl arc0
bioctl: BIOCINQ: Input/output error
The card is detected as a arc-1680 instead of arc-1212 - maybe this is the
reason?
Cheers