On 03/04/2014 01:08 AM, Ian Romanick wrote:
> From: Ian Romanick <ian.d.roman...@intel.com>
> 
> Volume 4, part 1 of the Ivybridge PRM says, "Generally, the EWA
> approximation algorithm results in higher image quality than the legacy
> algorithm."  Using a classic anisotropic filtering "tunnel" demo, it
> appears that there is *no* anisotropic filtering on IVB without this bit
> set.
> 
> Signed-off-by: Ian Romanick <ian.d.roman...@intel.com>
> Cc: Eero Tamminen <eero.t.tammi...@intel.com>
> ---
>  src/mesa/drivers/dri/i965/gen7_sampler_state.c | 1 +
>  1 file changed, 1 insertion(+)
> 
> diff --git a/src/mesa/drivers/dri/i965/gen7_sampler_state.c 
> b/src/mesa/drivers/dri/i965/gen7_sampler_state.c
> index 968c410..709a783 100644
> --- a/src/mesa/drivers/dri/i965/gen7_sampler_state.c
> +++ b/src/mesa/drivers/dri/i965/gen7_sampler_state.c
> @@ -82,6 +82,7 @@ gen7_update_sampler_state(struct brw_context *brw, int 
> unit, int ss_index,
>     if (gl_sampler->MaxAnisotropy > 1.0) {
>        sampler->ss0.min_filter = BRW_MAPFILTER_ANISOTROPIC;
>        sampler->ss0.mag_filter = BRW_MAPFILTER_ANISOTROPIC;
> +      sampler->ss0.aniso_algorithm = 1;
>  
>        if (gl_sampler->MaxAnisotropy > 2.0) {
>        sampler->ss3.max_aniso = MIN2((gl_sampler->MaxAnisotropy - 2) / 2,

*No* anisotropic filtering is a surprising result, but I can confirm
that enabling the EWA algorithm significantly changes the rendering in
one test I've looked at.  Without it, you get something like a polar
rose, and with it, you get a circle (which is the expected result).

So I think we should go ahead with this.