So last year I  played with using a Linux or Windows computer as a terminal 
using REXCPM.  I found that doing a 'stat con:=uc1:’ does indeed redirect the 
CP/M console I/O to the serial port and was somewhat successful using it that 
way.  Doing 'stat con:=crt:’ sets only the output to the RS232port.  ‘Stat 
con:=tty:’  sets I/O back to the M100 keyboard and screen.  I did have to 
configure a terminal type for some screen oriented software and usually chose 
VT52 ( H19) or VT100 if available, then used a terminal program such as minicom 
(VT100) or,  on a DOS machine I tried Procomm+ which had older terminal types  
available like H19, VT52, ADM and Televideo.  I used 9600 baud , no parity, no 
flow control to setup the serial port using the PC terminal program and the 
M100 Telcom program (88N1D) .  I think I also tried 19200 baud with no problem. 
 

Only problems I found were:
1. Need to use the F1 to toggle Sc L to Sc S to keep the screen from halting 
after every 8 lines. Some programs also work better if F2 is used to changed to 
Cu S.
2. Needed to re-adjust the CPM software to expect 24 lines/80 col instead of 
8lines/40col ( if your Model 100 CPM SW had been adjusted to 8 screen lines.
3. Some Software ( Infocom games?)  needed to see one <CR> from the model 100 
keyboard before it switched to the full sized keyboard attached to the PC. 
Weird.

Also I noticed that whenever a warm boot occurs, via CTRL-C or by a program,  
the user number reverts to user 0 regardless of the user you are logged into.  
This makes it less convenient to run programs from any user other than user 0.  
I don’t “think” a warm-boot I supposed to change the user number back to 0.  I 
know it doesn’t  do that on any 8- bit CP/M machine I own (Kaypro 2/4/10, 
Osborn I , NEC PC8801A, Televideo TPC-1).   I think this may have been 
discussed a while back on this mailing list….

I really enjoyed trying my old CP/M software on the M100.  Brings back my late 
70’s early 80’s memories of personal computer development.   We’ve come a long 
way since then.

Hope you all have a great holiday season.

Ron Klein

Sent from Mail for Windows

From: [email protected]
Sent: Tuesday, November 16, 2021 15:00
To: [email protected]
Subject: M100 Digest, Vol 131, Issue 9

Send M100 mailing list submissions to
        [email protected]

To subscribe or unsubscribe via the World Wide Web, visit
        http://lists.bitchin100.com/listinfo.cgi/m100-bitchin100.com
or, via email, send a message with subject or body 'help' to
        [email protected]

You can reach the person managing the list at
        [email protected]

When replying, please edit your Subject line so it is more specific
than "Re: Contents of M100 digest..."


Today's Topics:

   1. Re-directing CP/M console to serial port in REXCPM (Tom Hoppe)
   2. Re: Re-directing CP/M console to serial port in REXCPM
      (Jim Anderson)
   3. oh, and Hello again (Jim Anderson)
   4. Re: Re-directing CP/M console to serial port in REXCPM
      (Stephen Adolph)


----------------------------------------------------------------------

Message: 1
Date: Tue, 16 Nov 2021 10:50:12 -0800
From: Tom Hoppe <[email protected]>
To: [email protected]
Subject: [M100] Re-directing CP/M console to serial port in REXCPM
Message-ID:
        <CAPi0tM_gz1ASiCu1AvJNHS4mbU-oz3R9BQUQtY84=do47o0...@mail.gmail.com>
Content-Type: text/plain; charset="utf-8"

I am trying to re-direct the REXCPM console to the M100 serial port but
only having limited success. I am using 'stat con:=uc1:' to do the
re-direct. It seems to work for a minute, then stops. I am using minicom in
Linux and it works reliably using the REXCPM 'F3 toggle' feature to
re-direct only the screen output (19200 8N1). Has anyone else tried doing
this successfully?

Tom Hoppe
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://lists.bitchin100.com/private.cgi/m100-bitchin100.com/attachments/20211116/94027894/attachment-0001.html>

------------------------------

Message: 2
Date: Tue, 16 Nov 2021 19:21:35 +0000
From: Jim Anderson <[email protected]>
To: "[email protected]" <[email protected]>
Subject: Re: [M100] Re-directing CP/M console to serial port in REXCPM
Message-ID:
        
<yt2pr01mb43029435b6264d63354ea001f6...@yt2pr01mb4302.canprd01.prod.outlook.com>
        
Content-Type: text/plain; charset="utf-8"

First thought that comes to mind: it may be stopping because of the feature 
which pauses the screen output after 8 lines of consecutive output ? try 
Label-F1-Label to toggle ?Sc L? to ?Sc S? to disable this before redirecting 
the console?

I?m glad to see this post because I honestly had been thinking a while back 
that ?I wish there was a way to use a ps/2 keyboard with my MVT100 board as a 
full-blown terminal? but didn?t try anything because I?m not familiar enough 
with CP/M to know how to redirect the console like that.  What baud rate does 
it end up using when you do this?







        jim

From: M100 <[email protected]> On Behalf Of Tom Hoppe
Sent: Tuesday, November 16, 2021 10:50
To: [email protected]
Subject: [M100] Re-directing CP/M console to serial port in REXCPM

CAUTION External Sender: Do not click links or open attachments unless you 
recognize the sender and know the content is safe.

I am trying to re-direct the REXCPM console to the M100 serial port but only 
having limited success. I am using 'stat con:=uc1:' to do the re-direct. It 
seems to work for a minute, then stops. I am using minicom in Linux and it 
works reliably using the REXCPM 'F3 toggle' feature to re-direct only the 
screen output (19200 8N1). Has anyone else tried doing this successfully?

Tom Hoppe


-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://lists.bitchin100.com/private.cgi/m100-bitchin100.com/attachments/20211116/f12e631b/attachment-0001.html>

------------------------------

Message: 3
Date: Tue, 16 Nov 2021 19:31:29 +0000
From: Jim Anderson <[email protected]>
To: "[email protected]" <[email protected]>
Subject: [M100] oh, and Hello again
Message-ID:
        
<yt2pr01mb4302155131374437301a7db9f6...@yt2pr01mb4302.canprd01.prod.outlook.com>
        
Content-Type: text/plain; charset="us-ascii"

Sorry I vanished for most of this year - depression is not a good place to be.

I am hoping to get rolling and finish off the font redesign for the MVT100 
board I was working on last winter.  I think Stephen had started sharing the 
interim firmware I made which had initial M100 graphic characters added and 
some minor readability improvements to some of the characters (particularly the 
numbers 6 and 9).

I haven't been keeping up with this list, just filing the messages in the hope 
I'd pull myself up and start reading them - it's quite the backlog so I don't 
know if I will get there or not, so I don't know if I've missed any big 
developments in the REX or REXCPM worlds - I think the big one I was hoping for 
was a new 4mb CP/M image with more file handles/descriptors... and of course, 
the first message I read in a long time this morning stirred some hope of using 
the M100 CP/M with an external keyboard when stationary!

Glad to see you all again, and hope I can stay on top of things for a while.







        jim



------------------------------

Message: 4
Date: Tue, 16 Nov 2021 14:34:02 -0500
From: Stephen Adolph <[email protected]>
To: [email protected]
Subject: Re: [M100] Re-directing CP/M console to serial port in REXCPM
Message-ID:
        <camcmnv6jkspfla9eve8ccwh3u+p_n2fzlxjscmxp7jf7hao...@mail.gmail.com>
Content-Type: text/plain; charset="utf-8"

I think Philip Avery is probably best to comment on to what degree that is
supported.
It is a good question.

On Tue, Nov 16, 2021 at 2:21 PM Jim Anderson <[email protected]> wrote:

> First thought that comes to mind: it may be stopping because of the
> feature which pauses the screen output after 8 lines of consecutive output
> ? try Label-F1-Label to toggle ?Sc L? to ?Sc S? to disable this before
> redirecting the console?
>
>
>
> I?m glad to see this post because I honestly had been thinking a while
> back that ?I wish there was a way to use a ps/2 keyboard with my MVT100
> board as a full-blown terminal? but didn?t try anything because I?m not
> familiar enough with CP/M to know how to redirect the console like that.
> What baud rate does it end up using when you do this?
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>         jim
>
>
>
> *From:* M100 <[email protected]> *On Behalf Of *Tom Hoppe
> *Sent:* Tuesday, November 16, 2021 10:50
> *To:* [email protected]
> *Subject:* [M100] Re-directing CP/M console to serial port in REXCPM
>
>
>
> *CAUTION External Sender:* Do not click links or open attachments unless
> you recognize the sender and know the content is safe.
>
>
>
> I am trying to re-direct the REXCPM console to the M100 serial port but
> only having limited success. I am using 'stat con:=uc1:' to do the
> re-direct. It seems to work for a minute, then stops. I am using minicom in
> Linux and it works reliably using the REXCPM 'F3 toggle' feature to
> re-direct only the screen output (19200 8N1). Has anyone else tried doing
> this successfully?
>
>
>
> Tom Hoppe
>
>
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://lists.bitchin100.com/private.cgi/m100-bitchin100.com/attachments/20211116/a025ae0e/attachment-0001.html>

------------------------------

Subject: Digest Footer

_______________________________________________
M100 mailing list
[email protected]
http://lists.bitchin100.com/listinfo.cgi/m100-bitchin100.com


------------------------------

End of M100 Digest, Vol 131, Issue 9
************************************

Reply via email to