Correct, VT100 emulation.

On Tue, Nov 16, 2021 at 2:15 PM Stephen Adolph <[email protected]> wrote:

> there will be escape characters flowing over serial in this case, so you
> need to ensure that does not mess with things.
> If I understand what is happening
>
> M100 ---->   PC  (video terminal character flow)
> M100 <----  PC  (input keyboard strokes)
>
> When you say the terminal works reliably using F3, you are using the PC as
> a display for CP/M, right?  And in this case, you selected VT100 emulation?
>
>
>
>
> On Tue, Nov 16, 2021 at 5:05 PM Tom Hoppe <[email protected]> wrote:
>
>> I left minicom set to 19200 8N1 and it worked (until it didn't). The Sc L
>> vs Sc S is a good point! I will try changing this tonight and see if
>> it helps. My ultimate goal is to ssh into my home PC from work so I can
>> play with CP/M during lunch :).
>>
>> Tom
>>
>>
>> On Tue, Nov 16, 2021 at 11:21 AM Jim Anderson <[email protected]>
>> wrote:
>>
>>> First thought that comes to mind: it may be stopping because of the
>>> feature which pauses the screen output after 8 lines of consecutive output
>>> – try Label-F1-Label to toggle ‘Sc L’ to ‘Sc S’ to disable this before
>>> redirecting the console?
>>>
>>>
>>>
>>> I’m glad to see this post because I honestly had been thinking a while
>>> back that “I wish there was a way to use a ps/2 keyboard with my MVT100
>>> board as a full-blown terminal” but didn’t try anything because I’m not
>>> familiar enough with CP/M to know how to redirect the console like that.
>>> What baud rate does it end up using when you do this?
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>         jim
>>>
>>>
>>>
>>> *From:* M100 <[email protected]> *On Behalf Of *Tom
>>> Hoppe
>>> *Sent:* Tuesday, November 16, 2021 10:50
>>> *To:* [email protected]
>>> *Subject:* [M100] Re-directing CP/M console to serial port in REXCPM
>>>
>>>
>>>
>>> *CAUTION External Sender:* Do not click links or open attachments
>>> unless you recognize the sender and know the content is safe.
>>>
>>>
>>>
>>> I am trying to re-direct the REXCPM console to the M100 serial port but
>>> only having limited success. I am using 'stat con:=uc1:' to do the
>>> re-direct. It seems to work for a minute, then stops. I am using minicom in
>>> Linux and it works reliably using the REXCPM 'F3 toggle' feature to
>>> re-direct only the screen output (19200 8N1). Has anyone else tried doing
>>> this successfully?
>>>
>>>
>>>
>>> Tom Hoppe
>>>
>>>
>>>
>>>