Hi, when selecting a large table with the mouse (table > screen, table was scrolled down during selection), I got the report below. Afterwards, LyX crashed. Michael ******************************************************** ABR: Array bounds read This is occurring while in: LyXTabular::GetCellNumber(int,int)const [stl_vector.h:195] InsetTabular::setPos(BufferView*,int,int)const [insettabular.C:1270] InsetTabular::insetMotionNotify(BufferView*,int,int,int) [insettabular.C:776] InsetText::insetMotionNotify(BufferView*,int,int,int) [insettext.C:889] InsetCollapsable::insetMotionNotify(BufferView*,int,int,int) [insetcollapsable.C:370] BufferView::Pimpl::workAreaMotionNotify(int,int,unsigned int) [BufferView_pimpl.C:542] SigC::ObjectSlot3_<void,int,int,unsigned int,BufferView::Pimpl>::callback(void*,int,int,unsigned int) [object_slot.h:347] SigC::Signal3<void,int,int,unsigned int,SigC::Marshal<void>>::emit(const int&,const int&,const unsigned int&) [slot.h:554] WorkArea::work_area_handler(flobjs_*,int,int,int,int,void*) [basic_signal.h:589] C_WorkArea_work_area_handler [WorkArea.C:58] fl_handle_it [objects.c] fl_handle_object [libforms.a] fl_handle_form [forms.c] do_interaction_step [forms.c] fl_treat_interaction_events [libforms.a] fl_check_forms [libforms.a] GUIRunTime::runTime() [GUIRunTime.C:86] LyXGUI::runTime() [lyx_gui.C:316] LyX::LyX(int*,char**) [lyx_main.C:179] main [main.C:38] _start [crt1.o] Reading 4 bytes from 0x1408bfc in the heap. Address 0x1408bfc is 1 byte past end of a malloc'd block at 0x1408a28 of 468 bytes. This block was allocated from: malloc [rtlib.o] __as__t6vector2Zt6vector2ZQ210LyXTabular10cellstructZt9allocator1ZQ210LyXTabular10cellstructZt9allocator1Zt6vector2ZQ210LyXTabular10cellstructZt9allocator1ZQ210LyXTabular10cellstructRCt6vector2Zt6vector2ZQ210LyXTabular10cellstructZt9allocator1ZQ210LyXTabu [stl_alloc.h:157] LyXTabular::Init(int,int,const LyXTabular*) [tabular.C:180] LyXTabular::ReadNew(const Buffer*,istream&,LyXLex&,const lyxstring&) [tabular.C:1274] LyXTabular::Read(const Buffer*,LyXLex&) [tabular.C:1260] LyXTabular::LyXTabular(const Buffer*,InsetTabular*,LyXLex&) [tabular.C:120] InsetTabular::read(const Buffer*,LyXLex&) [insettabular.C:184] Buffer::readInset(LyXLex&,Paragraph*&,int&,LyXFont&) [buffer.C:1499] Buffer::parseSingleLyXformat2Token(LyXLex&,Paragraph*&,Paragraph*&,const lyxstring&,int&,unsigned int&,LyXFont&) [buffer.C:1050] InsetText::read(const Buffer*,LyXLex&) [insettext.C:250] InsetCollapsable::read(const Buffer*,LyXLex&) [insetcollapsable.C:105] InsetFloat::read(const Buffer*,LyXLex&) [insetfloat.C:181] Buffer::readInset(LyXLex&,Paragraph*&,int&,LyXFont&) [buffer.C:1499] Buffer::parseSingleLyXformat2Token(LyXLex&,Paragraph*&,Paragraph*&,const lyxstring&,int&,unsigned int&,LyXFont&) [buffer.C:1050] Buffer::readLyXformat2(LyXLex&,Paragraph*) [buffer.C:364] Buffer::readFile(LyXLex&,Paragraph*) [buffer.C:1541] BufferList::readFile(const lyxstring&,bool) [bufferlist.C:403] BufferList::loadLyXFile(const lyxstring&,bool) [bufferlist.C:506] LyX::LyX(int*,char**) [lyx_main.C:129] main [main.C:38] _start [crt1.o] -- ====================================================================== Michael Schmitt phone: +49 451 500 3725 Institute for Telematics secretary: +49 451 500 3721 Medical University of Luebeck fax: +49 451 500 3722 Ratzeburger Allee 160 eMail: [EMAIL PROTECTED] D-23538 Luebeck, Germany WWW: http://www.itm.mu-luebeck.de ======================================================================