Jürgen Spitzmüller wrote:
Richard Heck wrote:
Well, shoot. It's not working for me either, any more. Very strange
this.
It's not that strange. The clause where the slider is disabled is not
necessarily called when the TOC is empty (only when the type list is empty,
which doesn't happen for me, there's always the one type "toc").
For what it's worth, I haven't been able to trigger the freeze if
I hide the slider altogether. Not that that's a solution. (Then again,
maybe it is, if it works. We could always swap the slider for a combo
box or something.
Please no.
Or if we're only getting the freeze when the TOC is
empty, go ahead and hide it.)
By the way, look at TocWidget::setTocModel(). It enables depthSL no
matter what. Shouldn't it be: depthSL->setEnabled(buttons_enabled)?
Should reconnectSelectionModel() be called there if buttons_enabled =
false? Unfortunately, changing the former by itself doesn't solve the
problem.
But you were on the right track. The attached patch fixes the problem for me.
John, could you please verify that?
It works for me too! Good work to both you and Richard!
Thanks,