Hi all, I have 3 devices connected to the SPI bus of the MPC8313. For the Chip Select (CS) signals 3 GPIOs of the controller are used. But the driver uses the inverse polarity of the CS either during the initialization or at the transfer - depending on the setup of the flattened device tree.
Here is what I discovered: The driver uses a polarity flag for each CS signal (the alow_flags array). These flags are set according to the 'gpios' property of the SPI node of the flattened device tree. Is it correct that alow_flags[x] = 1 means CSx is active low? During the initialization the driver sets the CS to the value of alow_flags[x]. I.e. CSx is High if alow_flags[x] = 1 and otherwise Low. The flags are used in the function mpc8xxx_spi_cs_control() to take care about the polarity when setting the appropriate GPIO pin. But the function mpc8xxx_spi_chipselect() that calls the mpc8xxx_spi_cs_control() takes also care about the polarity of the CS (bool pol = spi->mode & SPI_CS_HIGH). Lets assume alow_flags[x] = 1 and the property 'spi-cs-high' is not set for the SPI device. During initialization the driver sets the chip select signal 'x' to High (see of_mpc8xxx_spi_get_chipselects()). This is OK if the chip select is active low, because this disables the device on start-up. But during the transfer the chip select signal is High and after the transfer is completed the signal is set to Low. This is not the intended behavior for an active low chip select. I also tried to set alow_flags[x] = 0 for active low. In this case the transfer works, but the initial value for the CS is wrong (Low instead of High). The problem seems to be that the polarity is taken into account twice (as described above). So what would be the better solution: removing the usage of the alow_flags in mpc8xxx_spi_cs_control() or the variable 'pol' in mpc8xxx_spi_chipselect()? Best Regards Torsten Fleischer _______________________________________________ Linuxppc-dev mailing list Linuxppc-dev@lists.ozlabs.org https://lists.ozlabs.org/listinfo/linuxppc-dev