Hi Grant:

Am 27.04.09 19:36 schrieb(en) Grant Likely:
For completeness use: compatible = "fsl,mpc5200b-lpb","fsl,mpc5200-lpb","simple-bus"; Then it will work.

I doesn't. I had to add "fsl,lpb", without no localbus nodes show up. The file arch/powerpc/platforms/52xx/mpc52xx_common.c lists only "fsl,lpb" as "compatible". Or did I miss something here?

If this is on CS3, then reg should be:
               reg = <3 0x0 0x100>;            // 256 Bytes, 32 used

Ouch.  Sorry, that was the error.  Works perfectly now...

Thanks a lot for your help,
Albrecht.