On Tue, Mar 31, 2009 at 04:30:26PM -0400, Matthew L. Creech wrote:
> (Sorry if this is a dupe, but I think my first attempt was filtered out)

No, it's a dupe. :-)

> I'm trying to get Linux booting on a custom board based on the MPC8313
> ERDB, but there's no output after the console is transferred.  I get
> the following:
[snip]
> Serial: 8250/16550 driver, 4 ports, IRQ sharing disabled
> serial8250.0: ttyS0 at MMIO 0xe0004500 (irq = 16) is a 16550A
> console handover: boot [udbg0] -> real [ttyS0]
> serial8250.0: ttyS1 at MMIO 0xe0004600 (irq = 17) is a 16550A

Make sure that u-boot for your board (or whatever you're using) is
properly filling in the clock-frequency property of the serial port
nodes.

-Scott
_______________________________________________
Linuxppc-dev mailing list
Linuxppc-dev@ozlabs.org
https://ozlabs.org/mailman/listinfo/linuxppc-dev

Reply via email to