Anton Vorontsov wrote:
Currently it doesn't matter where the mdio nodes are placed, but with
power management support (i.e. when sleep = <> properties will take
effect), mdio nodes placement will become important: mdio controller
is a part of the ethernet block, so the mdio nodes should be placed
correctly. Otherwise we may wrongly assume that MDIO controllers are
available during sleep.

Suggested-by: Scott Wood <[email protected]>
Suggested-by: Kumar Gala <[email protected]>
Signed-off-by: Anton Vorontsov <[email protected]>
---
 arch/powerpc/boot/dts/gef_ppc9a.dts        |   39 ++++---
 arch/powerpc/boot/dts/gef_sbc310.dts       |   39 ++++---
 arch/powerpc/boot/dts/gef_sbc610.dts       |   39 ++++---
 arch/powerpc/boot/dts/mpc8641_hpcn.dts     |  157 +++++++++++++++-------------
 arch/powerpc/boot/dts/sbc8641d.dts         |  156 +++++++++++++++-------------
 arch/powerpc/platforms/86xx/gef_ppc9a.c    |    1 +
 arch/powerpc/platforms/86xx/gef_sbc310.c   |    1 +
 arch/powerpc/platforms/86xx/gef_sbc610.c   |    1 +
 arch/powerpc/platforms/86xx/mpc8610_hpcd.c |    1 +
 arch/powerpc/platforms/86xx/mpc86xx_hpcn.c |    1 +
 arch/powerpc/platforms/86xx/sbc8641d.c     |    1 +
 11 files changed, 237 insertions(+), 199 deletions(-)


Tested on ppc9a. Other GE Fanuc boards look sane.

Tested-by: Martyn Welch <[email protected]>

Martyn

--
Martyn Welch MEng MPhil MIET (Principal Software Engineer)   T:+44(0)1327322748
GE Fanuc Intelligent Platforms Ltd,        |Registered in England and Wales
Tove Valley Business Park, Towcester,      |(3828642) at 100 Barbirolli Square,
Northants, NN12 6PF, UK T:+44(0)1327359444 |Manchester,M2 3AB  VAT:GB 729849476
_______________________________________________
Linuxppc-dev mailing list
[email protected]
https://ozlabs.org/mailman/listinfo/linuxppc-dev