This is used in precisely one place which is in pseries specific platform code. There's no need to have the callback in eeh_ops since the platform chooses the EEH PE addresses anyway. The PowerNV implementation has always been a stub too so remove it.
Signed-off-by: Oliver O'Halloran <ooh...@gmail.com> Reviewed-by: Alexey Kardashevskiy <a...@ozlabs.ru> --- v2: Made "buid" in pseries_eeh_get_pe_addr() an unsigned long to match the pci_controller type. --- arch/powerpc/include/asm/eeh.h | 1 - arch/powerpc/platforms/powernv/eeh-powernv.c | 13 ------------ arch/powerpc/platforms/pseries/eeh_pseries.c | 22 ++++++++++---------- 3 files changed, 11 insertions(+), 25 deletions(-) diff --git a/arch/powerpc/include/asm/eeh.h b/arch/powerpc/include/asm/eeh.h index 9c5ba535f6a1..d619012281bd 100644 --- a/arch/powerpc/include/asm/eeh.h +++ b/arch/powerpc/include/asm/eeh.h @@ -220,7 +220,6 @@ struct eeh_ops { int (*init)(void); struct eeh_dev *(*probe)(struct pci_dev *pdev); int (*set_option)(struct eeh_pe *pe, int option); - int (*get_pe_addr)(struct eeh_pe *pe); int (*get_state)(struct eeh_pe *pe, int *delay); int (*reset)(struct eeh_pe *pe, int option); int (*get_log)(struct eeh_pe *pe, int severity, char *drv_log, unsigned long len); diff --git a/arch/powerpc/platforms/powernv/eeh-powernv.c b/arch/powerpc/platforms/powernv/eeh-powernv.c index 79409e005fcd..bcd0515d8f79 100644 --- a/arch/powerpc/platforms/powernv/eeh-powernv.c +++ b/arch/powerpc/platforms/powernv/eeh-powernv.c @@ -535,18 +535,6 @@ static int pnv_eeh_set_option(struct eeh_pe *pe, int option) return 0; } -/** - * pnv_eeh_get_pe_addr - Retrieve PE address - * @pe: EEH PE - * - * Retrieve the PE address according to the given tranditional - * PCI BDF (Bus/Device/Function) address. - */ -static int pnv_eeh_get_pe_addr(struct eeh_pe *pe) -{ - return pe->addr; -} - static void pnv_eeh_get_phb_diag(struct eeh_pe *pe) { struct pnv_phb *phb = pe->phb->private_data; @@ -1670,7 +1658,6 @@ static struct eeh_ops pnv_eeh_ops = { .init = pnv_eeh_init, .probe = pnv_eeh_probe, .set_option = pnv_eeh_set_option, - .get_pe_addr = pnv_eeh_get_pe_addr, .get_state = pnv_eeh_get_state, .reset = pnv_eeh_reset, .get_log = pnv_eeh_get_log, diff --git a/arch/powerpc/platforms/pseries/eeh_pseries.c b/arch/powerpc/platforms/pseries/eeh_pseries.c index 18a2522b9b5e..bcc72b9a5309 100644 --- a/arch/powerpc/platforms/pseries/eeh_pseries.c +++ b/arch/powerpc/platforms/pseries/eeh_pseries.c @@ -32,6 +32,8 @@ #include <asm/ppc-pci.h> #include <asm/rtas.h> +static int pseries_eeh_get_pe_addr(struct pci_dn *pdn); + /* RTAS tokens */ static int ibm_set_eeh_option; static int ibm_set_slot_reset; @@ -301,7 +303,7 @@ void pseries_eeh_init_edev(struct pci_dn *pdn) eeh_edev_dbg(edev, "EEH failed to enable on device (code %d)\n", ret); } else { /* Retrieve PE address */ - edev->pe_config_addr = eeh_ops->get_pe_addr(&pe); + edev->pe_config_addr = pseries_eeh_get_pe_addr(pdn); pe.addr = edev->pe_config_addr; /* Some older systems (Power4) allow the ibm,set-eeh-option @@ -431,8 +433,10 @@ static int pseries_eeh_set_option(struct eeh_pe *pe, int option) * It's notable that zero'ed return value means invalid PE config * address. */ -static int pseries_eeh_get_pe_addr(struct eeh_pe *pe) +static int pseries_eeh_get_pe_addr(struct pci_dn *pdn) { + int config_addr = rtas_config_addr(pdn->busno, pdn->devfn, 0); + unsigned long buid = pdn->phb->buid; int ret = 0; int rets[3]; @@ -443,18 +447,16 @@ static int pseries_eeh_get_pe_addr(struct eeh_pe *pe) * meaningless. */ ret = rtas_call(ibm_get_config_addr_info2, 4, 2, rets, - pe->config_addr, BUID_HI(pe->phb->buid), - BUID_LO(pe->phb->buid), 1); + config_addr, BUID_HI(buid), BUID_LO(buid), 1); if (ret || (rets[0] == 0)) return 0; /* Retrieve the associated PE config address */ ret = rtas_call(ibm_get_config_addr_info2, 4, 2, rets, - pe->config_addr, BUID_HI(pe->phb->buid), - BUID_LO(pe->phb->buid), 0); + config_addr, BUID_HI(buid), BUID_LO(buid), 0); if (ret) { pr_warn("%s: Failed to get address for PHB#%x-PE#%x\n", - __func__, pe->phb->global_number, pe->config_addr); + __func__, pdn->phb->global_number, config_addr); return 0; } @@ -463,11 +465,10 @@ static int pseries_eeh_get_pe_addr(struct eeh_pe *pe) if (ibm_get_config_addr_info != RTAS_UNKNOWN_SERVICE) { ret = rtas_call(ibm_get_config_addr_info, 4, 2, rets, - pe->config_addr, BUID_HI(pe->phb->buid), - BUID_LO(pe->phb->buid), 0); + config_addr, BUID_HI(buid), BUID_LO(buid), 0); if (ret) { pr_warn("%s: Failed to get address for PHB#%x-PE#%x\n", - __func__, pe->phb->global_number, pe->config_addr); + __func__, pdn->phb->global_number, config_addr); return 0; } @@ -839,7 +840,6 @@ static struct eeh_ops pseries_eeh_ops = { .init = pseries_eeh_init, .probe = pseries_eeh_probe, .set_option = pseries_eeh_set_option, - .get_pe_addr = pseries_eeh_get_pe_addr, .get_state = pseries_eeh_get_state, .reset = pseries_eeh_reset, .get_log = pseries_eeh_get_log, -- 2.26.2