On 03/03/17 15:21, Vaibhav Jain wrote:
Had a short chat discussion with Gavin Shan on this patchset and he
preffers restoring the freeze_count on the eeh_pe once FRESET is done.
He expects a the flow to be similar to one below
1. module caches the value of freeze_count and resets it
2. Issue warm reset
3. During eeh error-detected callback module restores the freeze_count
from the cached value.
I'm inclined to think that's unnecessarily complex for relatively
limited gain - I can't imagine there's that many people reflashing their
CAPI devices so many times in quick succession that the counter won't
hit 5 in a real failure case.
--
Andrew Donnellan OzLabs, ADL Canberra
andrew.donnel...@au1.ibm.com IBM Australia Limited