On Thursday 11 October 2007, Valentine Barshak wrote: > Currently find_legacy_serial_ports() can find no serial ports on the OPB > with flattened device. Thus no legacy boot console can be initialized. > Just the early udbg console works, which is initialized with udbg_init_44x_as1 > on the UART's physical address specified in kernel config. This happens > because we look for ns16750 serial devices only and expect opb node to have > a device type property. This patch makes it look for ns16550-compatible > devices and use of_device_is_compatible() for opb in case device type is not > specified. > > Signed-off-by: Valentine Barshak <[EMAIL PROTECTED]>
Looks correct for QS21 now. Acked-by: Arnd Bergmann <[EMAIL PROTECTED]> _______________________________________________ Linuxppc-dev mailing list Linuxppc-dev@ozlabs.org https://ozlabs.org/mailman/listinfo/linuxppc-dev