Hi,

On 11/14/2018 3:41 AM, Felipe Balbi wrote:
> Thinh Nguyen <thinh.ngu...@synopsys.com> writes:
>
>> DWC_usb31 peripheral v1.70a-ea06 and prior needs a SW workaround for
>> isoc START TRANSFER command failure. However, some affected versions may
>> have RTL patches to fix this without a SW workaround. Add this quirk to
>> disable the SW workaround when it is not needed.
>>
>> Synopsys STAR 9001202023: Wrong microframe number for isochronous IN
>> endpoints.
>>
>> Signed-off-by: Thinh Nguyen <thi...@synopsys.com>
> unfortunately, does't apply to testing/next. Could you rebase??
>
Done.

Thanks,
Thinh