Selamlar,
CEntos 5 üzerinde hylafax kullanmaktayım fax modemim Zyxel Omni 56k harici modemi. fax gondermeye kalktıgım zaman aldıgım hata cıktısı asagıdaki gibi. Dec 1 20:13:52 localhost FaxGetty[5049]: OPEN /dev/ttyIAX1 HylaFAX (tm) Version 4.3.10 Dec 1 20:14:01 localhost FaxGetty[5049]: MODEM WWW.SOFT-SWITCH.ORG spandsp/ Dec 1 20:14:03 localhost FaxGetty[5049]: LOCKWAIT Dec 1 20:14:06 localhost FaxQueuer[5039]: NOTIFY: bin/notify.php "sendq/q6" "blocked" "" Dec 1 20:14:06 localhost FaxQueuer[5039]: NOTIFY exit status: 0 (5054) Dec 1 20:14:12 localhost FaxSend[5053]: MODEM WWW.SOFT-SWITCH.ORG spandsp/ Dec 1 20:14:12 localhost FaxSend[5053]: SEND FAX: JOB 5 DEST 92384885 COMMID 000000027 DEVICE '/dev/ttyIAX1' FROM 'Servet <[email protected]>' USER Servet Dec 1 20:14:16 localhost FaxSend[5053]: SEND FAILED: JOB 5 DEST 92384885 ERR Busy signal detected Dec 1 20:14:16 localhost FaxQueuer[5039]: NOTIFY: bin/notify.php "sendq/q6" "requeued" "" "20:17" Dec 1 20:14:16 localhost FaxQueuer[5039]: NOTIFY: bin/notify.php "sendq/q5" "requeued" "" "20:17" Dec 1 20:14:16 localhost FaxQueuer[5039]: NOTIFY exit status: 0 (5057) Dec 1 20:14:16 localhost FaxQueuer[5039]: NOTIFY exit status: 0 (5058) aslında hattım besgul degil ve karsı tarafta da hat mesgul degil. config dosyam asağıdaki gibidir. CountryCode: 90 AreaCode: 324 FAXNumber: 2383523 LongDistancePrefix: 0 InternationalPrefix: 00 DialStringRules: etc/dialrules ServerTracing: 1 SessionTracing: 11 RecvFileMode: 0666 LogFileMode: 0644 DeviceMode: 0644 RingsBeforeAnswer: 0 SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "NothingSetup" TagLineFont: etc/lutRS18.pcf TagLineFormat: "From %%l|%c|Page %%P of %%T" MaxRecvPages: 25 NotifyCmd: bin/notify.php # ModemType: Class1.0 # use this to supply a hint ModemRate: 19200 # rate for DCE-DTE communication ModemFlowControl: xonxoff # XON/XOFF flow control assumed # #ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem #ModemSetupDCDCmd: AT&C1 # setup so DCD follows carrier #GettyArgs: "-h %l dx_%s" # modem must auto-detect fax/data # # We can append the "@" symbol to the dial string so that # the modem will wait 5 seconds before attempting to connect # and return result codes that distinguish between no carrier # and no answer. This makes it possible to avoid problems with # repeatedly dialing a number that doesn't have a fax machine # (kudos to Stuart Lynne for this trick.) # # NB: If you need to prefix phone numbers to get through a PBX, # put it in the ModemDialCmd; e.g. "DT9%s@". # ModemDialCmd: ATX3DT%s # T for tone dialing # # Other possible configuration stuff. The default strings are #ModemResetCmds: "" # stuff to do when modem is reset ModemAnswerCmd: ATA # use this to answer phone ModemNoFlowCmd: AT&K # disable flow control cmd ModemHardFlowCmd: AT&K3 # hardware flow control cmd ModemSoftFlowCmd: AT&K4 # software flow control cmd #ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer # # Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH. # Note that we both turn the speaker on/off and set volume. # #ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1" ModemEchoOffCmd: ATE0 # disable command echo #ModemVerboseResultsCmd: ATV1 # enable verbose command results ModemResultCodesCmd: ATQ0 # enable result codes ModemOnHookCmd: ATH0 # place phone on hook (hangup) ModemSoftResetCmd: ATZ # do soft reset of modem ModemSoftResetCmdDelay: 3000 # pause after soft reset ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier #ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds #ModemRecvFillOrder: LSB2MSB # bit order of received facsimile #ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit # Class1Cmd: AT+FCLASS=1 # command to enter class 1 Class1PPMWaitCmd: AT+FTS=7 # command to stop and wait before PPM Class1TCFWaitCmd: AT+FTS=7 # command to stop and wait before TCF Class1EOPWaitCmd: AT+FTS=9 # command to stop and wait before EOP Class1SwitchingCmd: AT+FRS=7 # silence between HDLC recv and trans Class1TrainingRecovery: 1500 # 1.5sec delay after training failure Class1RecvAbortOK: 200 # wait 200ms for abort response Class1FrameOverhead: 4 # 4 byte overhead in recvd HDLC frames Class1RecvIdentTimer: 40000 # 35+5secs waiting for ident frames Class1TCFMaxNonZero: 10 # max 10% of data may be non-zero Class1TCFMinRun: 1000 # min run is 2/3rds of TCF duration Acaba nerede hata yapıyorum ? Teşekkür ederim saygılar. Servet TAŞ _______________________________________________ Linux-sunucu E-Posta Listesi [email protected] Liste kurallarını http://liste.linux.org.tr/kurallar.php bağlantısından okuyabilirsiniz; Bu Listede neden bulunduğunuzu bilmiyorsanız veya artık bu listeden gelen e-postaları almak istemiyorsanız aşağıdaki bağlantı adresini kullanarak 1 dakika içinde üyeliğinizi sonlandırabilirsiniz. https://liste.linux.org.tr/mailman/listinfo/linux-sunucu