From: Murthy Bhat <murthy.b...@microsemi.com>

return -EINPROGRESS when a rescan worker is queued.

Reviewed-by: Scott Benesh <scott.ben...@microsemi.com>
Reviewed-by: Kevin Barnett <kevin.barn...@microsemi.com>
Signed-off-by: Murthy Bhat <murthy.b...@microsemi.com>
Signed-off-by: Don Brace <don.br...@microsemi.com>
---
 drivers/scsi/smartpqi/smartpqi_init.c |    2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/scsi/smartpqi/smartpqi_init.c 
b/drivers/scsi/smartpqi/smartpqi_init.c
index 159e9cfc2996..61371ea35bb3 100644
--- a/drivers/scsi/smartpqi/smartpqi_init.c
+++ b/drivers/scsi/smartpqi/smartpqi_init.c
@@ -2243,7 +2243,7 @@ static int pqi_scan_scsi_devices(struct pqi_ctrl_info 
*ctrl_info)
 
        if (!mutex_trylock(&ctrl_info->scan_mutex)) {
                pqi_schedule_rescan_worker_delayed(ctrl_info);
-
+               rc = -EINPROGRESS;
        } else {
                rc = pqi_update_scsi_devices(ctrl_info);
                if (rc)