On 11/03/2017 11:56 PM, James Smart wrote:
> The driver does not respond to PLOGI from the direct attach target.
> The driver uses incorrect S_ID in CONFIG_LINK, after FLOGI completion
> 
> Correct by issuing CONFIG_LINK with the correct S_ID after receiving
> the PLOGI from the target
> 
> Signed-off-by: Dick Kennedy <[email protected]>
> Signed-off-by: James Smart <[email protected]>
> ---
>  drivers/scsi/lpfc/lpfc_els.c | 36 ++++++++++++++++++++----------------
>  1 file changed, 20 insertions(+), 16 deletions(-)
> 
Reviewed-by: Hannes Reinecke <[email protected]>

Cheers,

Hannes
-- 
Dr. Hannes Reinecke                Teamlead Storage & Networking
[email protected]                                   +49 911 74053 688
SUSE LINUX GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: F. Imendörffer, J. Smithard, J. Guild, D. Upmanyu, G. Norton
HRB 21284 (AG Nürnberg)

Reply via email to