According to datasheet, Page 8, minimum wait time to complete
measurement is 10ms. Adjusting this value will increase the
userspace polling rate.

Fixes: abeb6b1e7b ("iio: magnetometer: Add support for MEMSIC MMC35240")
Signed-off-by: Daniel Baluta <daniel.bal...@intel.com>
---
 drivers/iio/magnetometer/mmc35240.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/iio/magnetometer/mmc35240.c 
b/drivers/iio/magnetometer/mmc35240.c
index 7fff38e..7bc72b3 100644
--- a/drivers/iio/magnetometer/mmc35240.c
+++ b/drivers/iio/magnetometer/mmc35240.c
@@ -219,7 +219,8 @@ static int mmc35240_take_measurement(struct mmc35240_data 
*data)
                        return ret;
                if (reg_status & MMC35240_STATUS_MEAS_DONE_BIT)
                        break;
-               msleep(20);
+               /* minimum wait time to complete measurement is 10 ms */
+               usleep_range(10000, 11000);
        }
 
        if (tries < 0) {
-- 
1.9.1

--