Temperature reads on bmp280 device always return 0,
due to a missing step in the compensation formula
(data->tfine is never initialized).

Initialize data->tfine value so we get correct
temperature and pressure values.

Signed-off-by: Irina Tirdea <irina.tir...@intel.com>
---
 drivers/iio/pressure/bmp280.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/iio/pressure/bmp280.c b/drivers/iio/pressure/bmp280.c
index 7c623e2..a2602d8 100644
--- a/drivers/iio/pressure/bmp280.c
+++ b/drivers/iio/pressure/bmp280.c
@@ -172,6 +172,7 @@ static s32 bmp280_compensate_temp(struct bmp280_data *data,
        var2 = (((((adc_temp >> 4) - ((s32)le16_to_cpu(buf[T1]))) *
                  ((adc_temp >> 4) - ((s32)le16_to_cpu(buf[T1])))) >> 12) *
                ((s32)(s16)le16_to_cpu(buf[T3]))) >> 14;
+       data->t_fine = var1 + var2;
 
        return (data->t_fine * 5 + 128) >> 8;
 }
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to