Hi,

On Mon, Mar 09, 2015 at 01:53:58PM +0900, Beomho Seo wrote:
> >> remove the special handling of POWER_SUPPLY_PROP_CURRENT_MAX in 
> >> rt5033_get_charger_current() and do it like this:
> >>
> >> case POWER_SUPPLY_PROP_CURRENT_NOW:
> >>     val->intval = rt5033_get_charger_current(charger);
> >>     break;
> >> case POWER_SUPPLY_PROP_CURRENT_MAX:
> >>     val->intval = RT5033_CHG_MAX_CURRENT;
> >>     break;
> >>
> > 
> > OK. I will change comply with your comment.
> > 
> 
> RT5033_CHG_MAX_CURRENT is register value(hex).
> So It is better:
> 
> case POWER_SUPPLY_PROP_CURRENT_MAX:
>       val->intval = RT5033_CHARGER_FAST_CURRENT_MAX;
> 
> And then I will fix rt5033_get_charger_current function more readable.

Right, I copied the wrong value.

> [...]

-- Sebastian