We should move range when the measured value is greater than or equal to the max value not when greater than.
Signed-off-by: Charles Keepax <ckee...@opensource.wolfsonmicro.com> --- drivers/extcon/extcon-arizona.c | 4 ++-- 1 files changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/extcon/extcon-arizona.c b/drivers/extcon/extcon-arizona.c index f639f2a..5096919 100644 --- a/drivers/extcon/extcon-arizona.c +++ b/drivers/extcon/extcon-arizona.c @@ -388,7 +388,7 @@ static int arizona_hpdet_read(struct arizona_extcon_info *info) >> ARIZONA_HP_IMPEDANCE_RANGE_SHIFT; if (range < ARRAY_SIZE(arizona_hpdet_b_ranges) - 1 && - (val < 100 || val > 0x3fb)) { + (val < 100 || val >= 0x3fb)) { range++; dev_dbg(arizona->dev, "Moving to HPDET range %d\n", range); @@ -401,7 +401,7 @@ static int arizona_hpdet_read(struct arizona_extcon_info *info) } /* If we go out of range report top of range */ - if (val < 100 || val > 0x3fb) { + if (val < 100 || val >= 0x3fb) { dev_dbg(arizona->dev, "Measurement out of range\n"); return ARIZONA_HPDET_MAX; } -- 1.7.2.5 -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majord...@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/