cpufreq driver for EXYNOS5250 is not a platform driver, hence we cannot
currently pass the clock names through a device tree node. Instead, we
need to make them available through a global alias.

cpufreq driver for EXYNOS5250 requires four clocks - 'armclk',
'mout_cpu', 'mout_mpll' and 'mout_apll'.

'armclk' has already been defined with an alias, 'mout_cpu', 'mout_mpll'
and 'mout_apll' are now defined with an alias.

Signed-off-by: Tushar Behera <tushar.beh...@linaro.org>
---
 drivers/clk/samsung/clk-exynos5250.c |    6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/clk/samsung/clk-exynos5250.c 
b/drivers/clk/samsung/clk-exynos5250.c
index 5c97e75..05d099d 100644
--- a/drivers/clk/samsung/clk-exynos5250.c
+++ b/drivers/clk/samsung/clk-exynos5250.c
@@ -208,10 +208,10 @@ struct samsung_fixed_factor_clock 
exynos5250_fixed_factor_clks[] __initdata = {
 };
 
 struct samsung_mux_clock exynos5250_mux_clks[] __initdata = {
-       MUX(none, "mout_apll", mout_apll_p, SRC_CPU, 0, 1),
-       MUX(none, "mout_cpu", mout_cpu_p, SRC_CPU, 16, 1),
+       MUX_A(none, "mout_apll", mout_apll_p, SRC_CPU, 0, 1, "mout_apll"),
+       MUX_A(none, "mout_cpu", mout_cpu_p, SRC_CPU, 16, 1, "mout_cpu"),
        MUX(none, "mout_mpll_fout", mout_mpll_fout_p, PLL_DIV2_SEL, 4, 1),
-       MUX(none, "sclk_mpll", mout_mpll_p, SRC_CORE1, 8, 1),
+       MUX_A(none, "sclk_mpll", mout_mpll_p, SRC_CORE1, 8, 1, "mout_mpll"),
        MUX(none, "mout_bpll_fout", mout_bpll_fout_p, PLL_DIV2_SEL, 0, 1),
        MUX(none, "sclk_bpll", mout_bpll_p, SRC_CDREX, 0, 1),
        MUX(none, "mout_vpllsrc", mout_vpllsrc_p, SRC_TOP2, 0, 1),
-- 
1.7.9.5

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/